Cable Size Calculator - Professional Electrical Cable Sizing Tool
Calculate the correct cable size for your electrical installation based on BS7671 and IEC 60364-5-52 standards
Free Professional Cable Size Calculator
Calculate voltage drop, current capacity, and recommended cable sizes instantly
⚡ Loading calculator...
What is a Cable Size Calculator?
A cable size calculator is an essential tool for electrical professionals that determines the appropriate cable cross-sectional area (measured in mm²) required for safe and efficient electrical installations. Our calculator considers multiple factors including load current, cable length, voltage drop limitations, installation method, and conductor material to recommend the optimal cable size.
Whether you're working on residential, commercial, or industrial projects, proper cable sizing is critical for safety, compliance, and cost-effectiveness. Undersized cables can overheat and pose fire risks, while oversized cables waste money and installation space.
Key Features of Our Cable Size Calculator
BS7671 Compliance
Full compliance with British Standard BS7671 (IET Wiring Regulations) for UK electrical installations
IEC 60364-5-52 Support
International standard calculations for global electrical projects
Voltage Drop Analysis
Automatic calculation of voltage drop percentage with 3% compliance limit
Current Capacity
Comprehensive current carrying capacity calculations for safe cable selection
Dual Conductor Support
Calculations for both copper and aluminum conductors with appropriate derating
Phase Configuration
Support for both single-phase (230V) and three-phase (415V) systems
Enter load in Amps or kilowatts (kW) for maximum convenience
How to Use the Cable Size Calculator
Select Standard: Choose between BS7671 (British) or IEC 60364 (International) standards
Conductor Type: Select copper or aluminum cable conductor
Phase Configuration: Choose single-phase or three-phase power supply
Voltage: Select 230V for single-phase or 415V for three-phase
Installation Method: Choose how the cable will be installed (clipped direct, in conduit, etc.)
Load Value: Enter the electrical load in Amps or kW
Cable Length: Input the cable run length in meters
Power Factor: Enter the power factor (typically 0.8 for mixed loads, 0.95 for motor loads)
Calculate: Click the calculate button to get instant results
The calculator will instantly provide the recommended minimum cable size, calculated current, maximum current rating, voltage drop in volts, and voltage drop percentage.
Understanding Electrical Standards
BS7671 - British Standard for Electrical Installations
BS7671, also known as the IET Wiring Regulations, is the national standard in the United Kingdom for electrical installation and safety. It covers the design, erection, and verification of electrical installations to protect persons, property, and livestock from electric shock, fire, and burns. The current edition is BS7671:2018+A2:2022.
IEC 60364-5-52 - International Electrical Standard
IEC 60364-5-52 is the international standard for selection and erection of electrical equipment - wiring systems. It's widely used across Europe and many other countries. This standard provides guidelines for cable selection, current-carrying capacity, and voltage drop calculations.
Maximum Voltage Drop Requirements
Both BS7671 and IEC 60364-5-52 specify maximum voltage drop limits:
Lighting circuits: Maximum 3% voltage drop
Other uses (power circuits): Maximum 5% voltage drop
This calculator uses a conservative 3% limit for all calculations
Cable Sizing Factors
Current Carrying Capacity
The cable must be able to carry the full load current continuously without overheating. Current ratings depend on conductor material (copper has higher capacity than aluminum), cable size, insulation type, and installation method.
Voltage Drop
As current flows through a cable, resistance causes voltage drop. Longer cables and higher currents result in greater voltage drop. The voltage at the load end must remain within acceptable limits (typically 3-5% of supply voltage).
Installation Method
How a cable is installed significantly affects its ability to dissipate heat:
Free air: Best heat dissipation, highest current capacity
Clipped direct: Good heat dissipation, common for surface mounting
In conduit: Reduced heat dissipation, requires derating
In thermal insulation: Worst heat dissipation, significant derating required
Conductor Material
Copper and aluminum are the two primary conductor materials:
Copper: Higher conductivity, higher current capacity, more expensive, industry standard
Aluminum: Lower conductivity, requires larger cable sizes, lighter weight, more economical for large cables
Standard Cable Sizes
Standard cable cross-sectional areas (in mm²) available in this calculator:
1.5mm² - Typical for lighting circuits
2.5mm² - Standard for socket outlets
4mm² - Heavy domestic loads, small commercial
6mm² - Cookers, showers, small commercial equipment
10mm² - Large domestic loads, commercial circuits
16mm², 25mm², 35mm² - Commercial and light industrial
50mm², 70mm², 95mm² - Industrial applications
120mm², 150mm², 185mm², 240mm², 300mm² - Heavy industrial and distribution
Safety and Compliance
Important: This calculator provides guidance for cable sizing based on standard conditions and typical installation scenarios. Always ensure that:
All electrical work is performed by qualified, competent persons
Local electrical codes and regulations are followed
Proper installation practices and safety procedures are observed
Cable specifications meet or exceed calculated requirements
Environmental factors (temperature, grouping, etc.) are considered
Appropriate protective devices (MCBs, RCDs) are installed
Installation is tested and certified upon completion
This calculator is provided as a design tool and guide only. It should not replace professional engineering judgment or official electrical design documentation. Always consult with a qualified electrician or electrical engineer for critical installations.
Frequently Asked Questions
What is the difference between cable size and current rating?
Cable size refers to the cross-sectional area of the conductor (measured in mm²), while current rating is the maximum current the cable can safely carry continuously. Larger cable sizes have higher current ratings. The current rating depends on both the cable size and the installation method.
Why does installation method matter?
Installation method affects how well a cable can dissipate heat. Cables in free air cool better than cables buried in insulation. Poor heat dissipation reduces the safe current carrying capacity, requiring larger cable sizes.
Can I use a larger cable than calculated?
Yes, using a larger cable than calculated is safe and may be beneficial. It provides additional safety margin, reduces voltage drop further, and allows for future load increases. However, it also increases material and installation costs.
What if my voltage drop exceeds 3%?
If voltage drop exceeds 3%, you should use a larger cable size. High voltage drop can cause poor performance of equipment, dimming lights, motor problems, and inefficiency. The calculator will recommend the next larger size to bring voltage drop within limits.
How do I account for grouped cables?
When multiple cables are grouped together (in the same conduit or cable tray), they cannot dissipate heat as effectively. This requires applying grouping factors (derating factors) to reduce the effective current rating. For precise calculations with grouped cables, consult BS7671 or IEC 60364-5-52 for appropriate derating factors.
When in doubt, use 0.8 as a conservative estimate.
Is this calculator suitable for DC circuits?
This calculator is designed for AC circuits (single-phase and three-phase). DC circuits have different voltage drop calculations and don't use power factor. For DC applications, consult DC-specific cable sizing tools or standards.
About Cable Size Calculator
Cable Size Calculator is a free, professional-grade tool designed to help electrical professionals, engineers, contractors, and students accurately determine cable sizes for electrical installations. Our calculator implements the latest standards and provides instant, reliable results for safe and compliant electrical design.
Whether you're designing residential wiring, commercial electrical systems, or industrial power distribution, our calculator provides the accuracy and reliability you need for professional electrical design work.
Cable Size Calculator
Calculate the appropriate cable size for your electrical installation based on British (BS7671) or International (IEC 60364-5-52) standards
Input Parameters
Results
Enter parameters and click Calculate to see results
About This Calculator
This cable calculator helps determine the appropriate cable size for electrical installations based on British (BS7671) and International (IEC 60364-5-52) standards.
The calculator considers current carrying capacity and voltage drop to recommend the minimum cable size that meets both requirements. The voltage drop is limited to 3% as per standard regulations.
Important: These calculations are provided as a guide only. Always consult with a qualified electrician and comply with local electrical codes and regulations before installation.